Netherland Phase Change Material Cooling Building Construction Finoric LLC
Tel: 773-829-5811
Email: info@finoric.com

Home ---------------- Contact

Jumbo bulk bags Drum Packing Tote Paletized Packing Drums paletized Netherland Phase Change Material Cooling Building Construction Rotterdam Floating Balls. PCM AC

PCM Cooling Phase Change Material Air Condition AC Dallas Houston Austin Texas, Atlanta Georgia Manufacturers

If you are versed with Phase Change Material, then you may directly read the matter below the horizontal line. If you need to understand more then you may go in the following order:

Introduction to PCM Air Condition
Phase Change Material Non Hazardous Salts
Peak Load Shifting in AC Air Condition

After reading this much you may shift below the horizontal line. You may also check the following pages:

Energy Saving tips for Lighting, Insulation and Windows, Renewable Energy, Air Change Rate etc
Phase Change Material for Electronic Comfort
PCM for Green House.


We are authorized representative of PCM Energy P Ltd. for Phase Change Material PCM and related products. Described below is the scheme for Air-conditioning with PCM in Dallas, Houston Austin Texas & Atlanta Georgia. We will shortly put up pages for the benefit of other areas in USA. To benefit serious players in HVAC, we will start with the average climate in Dallas. Such an information is available for all the major cities of USA in weather related websites. If you are not already versed with PCM-AC, then please study similar scheme for Houston is described by Phase change material air conditioner or you may start on this website with Introduction to PCM Air Condition

Dallas Average Temperature:

Mon - High - Low# - ΔT - Mid-way Comments
Jan - 54F - 34F - 20 - Can not balance Use heater during non-peak electric tariff hours
Feb - 60F - 39F - 21 - Can not balance Use heater during non-peak electric tariff hours
Mar - 68F - 46F - 22 - Can not balance Use heater during non-peak electric tariff hours
Apr - 76F - 54F - 22 - Balance @ 65F Cools & Heats with PCM 80+75
May - 83F - 63F - 20 - Balance @ 73F Cools & Heats with PCM 80+75
Jun - 91F - 70F - 21 - Balance @ 80F Cools & Heats with PCM 80+75
Jul - 95F - 75F - 20 - Balance @ 85F Cools & Heats with PCM 80+75
Aug - 95F - 74F - 21 - Balance @ 84F Cools & Heats with PCM 80+75
Sep - 88F - 67F - 21 - Balance @ 77F Cools & Heats with PCM 80+75
Oct - 78F - 56F - 22 - Balance @ 67F Cools & Heats with PCM 80+75
Nov - 65F - 45F - 20 - Can not balance Use heater during non-peak electric tariff hours
Dec - 57F - 37F - 20 - Can not balance Use heater during non-peak electric tariff hours

(Click for Climate in Houston -- Austin -- Atlanta)

Similar weather is also seen in Orlando Florida, Louisiana, Mississippi, Alabama, South Carolina, Parts of New Mexico, Arizona and other southern areas of USA. Las Vegas is a little hotter and needs to be shifted to 77-78F balance.

A house of 1000sq.ft and 9ft height has a volume of 9000 cu. ft.

Sp. Heat of air is 1KJ/Kg/K; And density is 1.2Kg/M3
For 25F (25*5/9 =13.89K) change of temperature 1M3 of air will need 1.2*25*5/9KJ = 16.67KJ
1M3=35.29cu.ft. Hence 35.29cu.ft. needs 16.67KJ
9000cuft (i.e. the full volume of the house) needs 16.67*9000/35.29=4252KJ or 4252KJ/hr=4252/3600=1.18KWH
After adjusting for other losses it can go up to 2KWH
The ordinary forced air change rate is 0.35/hr and hence the wattage will be 2KWH/3hr
This 100F heat remains for maximum 3 hour. Average load for overlapping 12 hours will be half this value. This makes total load as 2+4=6 KWH. The rest of the time is cooling & charging period for PCM.
The blower capacity for PCM utilization is 52.5cfm=52.5*60 i.e.3150cuft/hr. We must buy a blower of 100cfm (Higher cfm is proposed as the blower may not give the rated output) and provide a regulator.

This means we must install 6KWH of PCM-80+75. Which is equal to 120kg or 265 lbs of PCM 50% of it melting at 80F and 50% melting at 75F. We may also install (optional) about 100lbs of PCM in walls.

Any company already in the business of HVAC or in developing new buildings in a big way can benefit tremendously by using this method. You can expect government support and carbon credits over and above the routine business benefits.

Phase Change Material Air Condition
This is a Thumbsnail for mobile screen. Please click to Enlarge

 

Click for PCM-AC in Richmond Virginia Columbus Ohio, Los Angeles, Washington DC, Baltimore, Kentucky Delaware Maryland Philadelphia Pennsylvania Cleveland Indianapolis Indiana Chicago Illinois.

You can use this scheme for malls, restaurants, halls warehouse etc.

Electronic Passive Cooling PCM Phase Change Material AC Cooling

Finoric LLC
Chicago Illinois and Houston Texas, USA. Tel: 773-829-5811
Email: info@finoric.com

Associates:
Finoric & Parenterals FZE, PO 10559 RAK Free Trade Zone, Ras Al Khaimah, UAE

We are looking for Technical Sales Representatives in New York and Los Angeles Area.

SiteMap.xml

Electronic Passive Cooling PCM Phase Change Material AC Cooling

HDPE PCM Filled PanelCeiling with PCM Rotterdam Floating Balls. PCM AC

Phase Change Material Bottles PCM in Molded Packs Vaccine Box Vaccine Box PCM Ball PCM Pipe

PCM Panel PCM Heat Exchnager Profile

Austin Average Temperature:

Mon - High - Low# - ΔT - Mid-way Comments
Jan - 60F - 40F - 20 - Can not balance Use heater during non-peak electric tariff hours
Feb - 65F - 44F - 21 - Can not balance Use heater during non-peak electric tariff hours
Mar - 72F - 51F - 21 - Can not balance Use heater during non-peak electric tariff hours
Apr - 79F - 58F - 21 - Balance @ 69F Cools & Heats with PCM 80+75
May - 85F - 65F - 20 - Balance @ 75F Cools & Heats with PCM 80+75
Jun - 91F - 71F - 20 - Balance @ 81F Cools & Heats with PCM 80+75
Jul - 95F - 73F - 22 - Balance @ 84F Cools & Heats with PCM 80+75
Aug - 96F - 73F - 23 - Balance @ 84F Cools & Heats with PCM 80+75
Sep - 90F - 69F - 21 - Balance @ 80F Cools & Heats with PCM 80+75
Oct - 81F - 59F - 22 - Balance @ 70F Cools & Heats with PCM 80+75
Nov - 70F - 49F - 21 - Can not balance Use heater during non-peak electric tariff hours
Dec - 62F - 42F - 20 - Can not balance Use heater during non-peak electric tariff hours

Houston Average Temperature:

Mon - High - Low# - ΔT - Mid-way Comments
Jan - 62F - 41F - 21 - Can not balance Use heater during non-peak electric tariff hours
Feb - 67F - 44F - 23 - Can not balance Use heater during non-peak electric tariff hours
Mar - 73F - 51F - 22 - Can not balance Use heater during non-peak electric tariff hours
Apr - 79F - 57F - 22 - Balance @ 68F Cools & Heats with PCM 80+75
May - 86F - 66F - 20 - Balance @ 76F Cools & Heats with PCM 80+75
Jun - 91F - 72F - 19 - Balance @ 81F Cools & Heats with PCM 80+75
Jul - 94F - 74F - 20 - Balance @ 84F Cools & Heats with PCM 80+75
Aug - 94F - 73F - 21 - Balance @ 84F Cools & Heats with PCM 80+75
Sep - 89F - 68F - 21 - Balance @ 78F Cools & Heats with PCM 80+75
Oct - 82F - 59F - 23 - Balance @ 70F Cools & Heats with PCM 80+75
Nov - 72F - 50F - 22 - Can not balance Use heater during non-peak electric tariff hours
Dec - 65F - 43F - 22 - Can not balance Use heater during non-peak electric tariff hours

Atlanta - Georgia Average Temperature:

Mon - High - Low# - ΔT - Mid-way Comments
Jan - 52F - 33F - 21 - Can not balance Use heater during non-peak electric tariff hours
Feb - 57F - 36F - 21 - Can not balance Use heater during non-peak electric tariff hours
Mar - 65F - 43F - 22 - Can not balance Use heater during non-peak electric tariff hours
Apr - 73F - 50F - 23 - Can not balance Use heater during non-peak electric tariff hours
May - 80F - 59F - 21 - Balance @ 76F Cools & Heats with PCM 80+75
Jun - 87F - 67F - 20 - Balance @ 81F Cools & Heats with PCM 80+75
Jul - 89F - 70F - 19 - Balance @ 84F Cools & Heats with PCM 80+75
Aug - 88F - 70F - 18 - Balance @ 84F Cools & Heats with PCM 80+75
Sep - 82F - 63F - 18 - Balance @ 78F Cools & Heats with PCM 80+75
Oct - 73F - 53F - 20 - Can not balance Use heater during non-peak electric tariff hours
Nov - 63F - 43F - 20 - Can not balance Use heater during non-peak electric tariff hours
Dec - 55F - 36F - 19 - Can not balance Use heater during non-peak electric tariff hours